Burst tests, commonly called burst pressure resistance tests, are typically carried out at pressures up to 1000 bar with different media at varying ambient temperatures.
Pressure range
- 0 - 1100 bar - standard
- > 1100 bar - to be agreed
Medium
- hydraulic oil
- water
- glycol
- brake fluid
- Other media, to be agreed
Temperature range
- from -40°C to +180°C
- from ambient temperature to +250°C
Pressure change shape
- practically any – to be agreed with the customer
- high accuracy of tracking the required pressure shape
Data acquisition
- Pressure and temperature data acquisition throughout the test
Tests may apply to
- Heat exchangers
- Brake Master Cylinders
- Brake Calipers
- Whell Brake Cylinder
- Brake lines
- Brake hoses
- and other
Charts: Examples of Burst Tests