The test in flowing mixed gas corrosion test allows to determine the corrosive effect of the working and storage environment on electrotechnical components, especially contacts, terminals and connections (considered both separately and as integrated into a component or assembled as a complete equipment).
 
Tested samples are placed in the AirEvent Gas/600/0 chamber under various temperature and humidity conditions, in the atmosphere of single corrosive gas or their mixture: 
  • Cl2
  • SO2
  • NO2
  • H2
Gases are mixed with together depending on the test method and/or Customer requirements. The working range of gases concentration is from 10 to 500 ppb.
 
Gases concentration are monitored with the use of SPM Flex analyser
 
Preferred test duration is 4, 7, 10, 14 or 21 days.

AirEvent Gas/600/0 chamber equipment

  • inner chamber for corrosion tests
  • concentration gas analyser SPM Flex which allows for actual gas concentration monitoring 
  • corrosive gases dosing system 
  • cabinet with ventilation and gas dosing system.

Test standards

  • IEC 60068-2-60
  • PN-EN 60512-11-14
  • ASTM B845-97
  • Renault 36-00-802
  • VW 80000 
  • and others, on request
 

Testing and measuring apparatus

  • AirEvent Gas/600/0 Weiss chamber, with internal capacity of 260 L, with internal dimensions (630x630x670) mm
  • corrosive gases dosing system 
  • SPM Flex Honeywell gas concentration analyser with chemocassettes
 
Document No. Title/Description
IEC 60068-2-60 Environmental testing - Part 2-60: Tests - Test Ke: Flowing mixed gas corrosion test
PN-EN 60512-11-14 Connectors for electronic equipment - tests and measurements - part 11-14: climatic tests - test 11p: flowing single gas corrosion test
ASTM B845-97 Mixed Flowing Gas (MFG) Tests for Electrical Contacts
Renault 36-00-802 Corporate standard
VW 80000 Electric and Electronic Components in Motor Vehicles up to 3.5 t. General Requirements, Test Conditions, and Tests