Tests of resistance to thermal shocks in a shock chamber (cyclic action of air)

Climats shock chamber

The shock chamber is designed to expose test samples to thermal shocks. Accurate simulations in accordance with standards (including defense standards) are possible. The shock test in the device is carried out by means of an automatically controlled elevator moving between chambers at two extreme temperatures: high and low. The device is a horizontal chamber, i.e. the working chambers are located side by side.
 
The shock chamber makes it possible to test the resistance of parts and devices to rapid temperature changes (i.e. thermal shocks).
 
Testing (PCA accredited range) according to the following norms:
 
  • PN-EN 60068-2-14
  • PN-EN 60068-2-1
  • PN-EN 60068-2-2
  • VW 80000 (K-16)
  • GS 95024-3-1 (K-05)
  • Others (within the technical capabilities of the chamber)
 
Basic technical parameters: 
 
  • Temperature range: -70 to +180 °C
  • Travel plane of the basket: horizontal
  • Basket capacity: 512 l
  • Dimensions of the basket: (80x80x80) cm
  • Max. basket load: 80 kg
  • Max. transition time: 10 s
Document No. Title/Description
PN-EN 60068-2-1:2009
PN-EN 60068-2-2:2009
PN-EN 60068-2-14:2009
VW 80000 (K-16) Electic and Electronic in Motor Vehicles up to 3,5T. General Requirements, Test Conditions and Tests. K-16 - Temperature Shock (without housing)
GS 95024-3-1 (K-05) Elektrische und elektronische Komponenten in Kraftfahrzeugen Umweltanforderungen und Prüfungen. K-05 Temperaturschock Methode Nc