Testing the electrical properties of conductive, antistatic and insulating materials

Measurements of surface resistance, bulk resistance and insulation resistance of conductive, antistatic and insulating materials

BOSMAL conducts measurements of surface, bulk and insulation resistance of conductive, antistatic and insulating materials in the range up to 1016 Ω at voltages of up to 1 kV (DC).

Test objects

  • plastic products,
  • rubbers,
  • fabric and Rother materials,
  • electrotechncial elements and subsystems.
In the photo: Agilent 4339B

Norms

Testing is carried out In accordance with:
  • PN-EN 61340-2-3
  • PN-EN 62631-3-1
  • PN-EN 62631-3-2
  • PN-EN 62631-3-3
  • ASTM D257
  • ISO 1853
  • ISO 2951
  • ISO 14309
  • ISO 16750-2 and others
In the photo: knife electrodes

Measurements of the electrical durability of insulating materials

Measurements of the electrical durability of insulating materials are performed in the following ranges:
  • 0 - 40 kVRMS (AC)
  • 0 - 8 kV (DC)

Test objects

  • insulation elements of electrotechnical components,
  • insulations for wires and wiring harnesses,
  • connector housing,
  • samples of insulating materials,
  • paint coatings; others.
In the photo: Hioki 3158 electrical durability tester

Norms

Testing is carried out in accordance with:
  • PN-EN 60243-1
  • PN-EN 60243-2
  • ISO 16750-2 and others.